Product name : GTD-5000Tx pumped oxygen and gas detector
Item : 美国英思科ISC
 Enlarge Image                   Back
←[Previous Product]              [Next Product]→


Details:
 

GTD-5000Tx pumped oxygen and gas detector

■ Built-in sampling pump, faster leak response

■ modular sensor, easy to replace

■ Modbus communication

■ PoE online detection

■ can measure oxygen and more than 100 kinds of toxic gases

■ Fixed gas flow



Overview


◤ use built-in sampling pump to achieve toxic gas / oxygen leak quickly respond

 Built-in microprocessor to achieve self-diagnostic function

◤ with a box sensor, the replacement is more simple

◤ use digital flow sensor to maintain a fixed flow

¢ long-term stability of the quality and proven test principle

 Detection of toxic gases below TLV (threshold), excellent performance

◤ excellent LCD display, display a variety of information

¢ 4-digit gas concentration monitor

◤ 4-20mA DC output signal

↑ Easily monitor system configuration by RS-485 Modbus isolated serial data communication or PoE (optional)

 Level 2 alarm, single fault display and relay contact output

◤ 3-wire system

 Single calibration and maintenance

Technical Parameters


Model GTD-5000Tx

Measurement of gas Oxygen / toxic gases (carbon monoxide, chlorine, ammonia, etc.)

Measuring method Pumping

Measuring methods for semiconductors, electrochemistry

Response time T90 <45 seconds

Accuracy ± 3% / full scale

Operation Front panel switch (calibration, maintenance, alarm settings)

Operation mode display 4-LED (power supply, level 2 alarm, single fault)

Display the LCD display (4 digits)

Alarm signal output 250V 1A / 3 SPD switch (SPST) Relay contact (2-level alarm, 1-fault)

Output signal 4 - 20mA DC

RS-485 Modbus (optional) / PoE (power over Ethernet) (optional)

Sampling method Diaphragm sampling pump

Sampling line OD: 1/4 inch (standard)

Flow maximum: 0 ~ 1000ml / min

Cable / distance power cable + signal cable: three lines> 1.5 square (AWG16) / maximum 1000 m / pyrolyzer maximum 500 m

RS-485 data communication cable: 1 pair (UL2919 RS-485) / maximum: 1000m

PoE (power over Ethernet): up to 100m

Pyrolysis type: up to 500 meters

Catheter Connection Cable Seal Kit (PG-16)

Installation Type Wall Mount Installation

Operating temperature -20 ℃ ~ +60 ℃

Operating Humidity 5 - 99% RH (non-condensing)

Operating power standard: 18 ~ 31 VDC (conventional 24 VDC) / maximum 280 mA

Pyrolysis device (Note 1): 18 to 31 VDC (conventional 24 VDC) / maximum 520 mA

PoE (Note 2): 48 VDC ± 10% / max 200 mA

Material front (polycarbonate), side (steel)

Size Standard: 70 (W) x 144 (H) x 160 (D) mm

Pyrolyzer type (PY-1000): 70 (width) x 242.5 (high) x 160 (deep) mm

Weight Standard: 2.5kg

GTD-5000 and PY-1000: 4.05 kg

Certification CE (EN50270: 1999)

Remark 1 Polyzer (PY1000, PY2000) Device current consumption

Note 2 When using PoE power supply, if you want to use pyrolysis device, should provide 24V DC


Related Products :
FMC-1000 plug-in alarm controller
美国华瑞(RAE)
FMC-1000 plug-in alarm controller
RAEGuards IR infrared combustible gas detector [FGM-1200S]
20131129202350
RAEGuards IR infrared combustible gas detector [FGM-1200S]
OLCT10 gas detector
法国奥德姆(OLDHAM)
OLCT10 gas detector
CEX 300 fixed gas detector
美国英思科(ISC)
CEX 300 fixed gas detector
GP-147 combustible gas alarm
日本理研(RIKEN)
GP-147 combustible gas alarm
UltraSonic EX-5 ultrasonic gas leak detectors
美国梅思安(MSA)
UltraSonic EX-5 ultrasonic gas leak detectors
GTD-2000Ex combustible gas detector
美国英思科ISC
GTD-2000Ex combustible gas detector
iTrans 2 gas detector
美国英思科(ISC)
iTrans 2 gas detector

online service

点击这里给我发消息 点击这里给我发消息